Harbor fan troubleshooting

ProblemPossible CauseCorrective Action
Fan does not move.1. Power is off or fuse is blown.1. Turn power on or check fuse.
2. Faulty wire connection.2. Turn power off. Loosen canopy (B) and check all connections.
3. Plugs and/or antenna wire not connected property.3. Check that male and female plugs and/or antenna wire in switch housing are connected properly according to instructions on page 8.
Noisy operation.1. Blades (H) are loose.1. Tighten all blade screws (I).
2. Cracked blade (H).2. Replace blade (H).
3. Full range dimmer switch.3. Replace with ON/OFF wall switch only.
4. Fan is new.4. Allow fan a “break in' period of a few days, especially when running the fan at Medium and High speeds.
Excessive wobbling.1. Blades (H) are loose.1. Tighten all blade screws (I).
2. Unbalanced blades (H).2. Switch one blade (H) with a blade (H) from the opposite side.
3. Fan not securely mounted.3. Turn power off. Carefully loosen canopy (B) and verify that mounting bracket (C) is secure.
4. Fan too close to vaulted ceiling.4. Use a longer down rod (A) or move fan to another location.
5. Set screw(s) on motor housing yoke is (are) not tightened property.5. Tighten yoke set screw(s) securely.
6. Set screw on hanging ball is not tightened properly.6. Carefully loosen and lower screw on canopy (B) and verify that set screw on hanging ball is tightened securely.
Fan operates but lights fail (if applicable).1. Bulb(s) not installed correctly.1. Re-install bulb(s).
2. Wires in canopy (B) not wired properly.2. Check wires in canopy (B) and, if necessary, re-wire according to instructions on page 6 and 7.
3. Wall switch to fan is off.3. Make sure that wall switch to fan is on.
4. Plugs and/or antenna wire not connected property.4. Check that male and female plugs and/or antenna wire in switch housing are connected properly according to instructions on page 8.
5. Light kit is lamped with more than the allowable 190W, causing the wattage limiting device to interrupt the flow of electricity to the light kit.5. Lamp light kit with bulbs that total no more than 190W.

Error codes and troubleshooting