Avanti refrigerator troubleshooting



Any modern refrigerator is a complex system, where the majority of parts interact with each other. In case of damage of one part, the entire system can fall out, if a breakdown is not corrected in time. The diagnostics of malfunction contributing to the further professional repairs of a refrigerator is the key objective of troubleshooting tables with faults` codes for avanti refrigerators presented below.

Avanti BCAD series refrigerator troubleshooting

Avanti BCA is an extensive lineup of refrigerators made by the consumer appliances manufacturer Avanti, based in Miami, FL. It includes beverage centers (some of them are built-in), as well as compact one-door refrigerators.

Avanti BCAD lineup is sometimes considered a part of the BCA series, but it has a number of specific options. The BCAD lineup was created for beverage coolers (centers) that are usually larger than those introduced in the BCA lineup.

PROBLEMPOSSIBLE CAUSE
Beverage Cooler does not operate.Not plugged in.
The appliance is turned off.
The circuit breaker tripped or a blown fuse.
Beverage Cooler is not cold enough.Check the temperature control setting. The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
Turns on and off frequently.The room temperature is hotter than normal.
A large amount of contents has been added to the Beverage Cooler.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly. The door gasket does not seal properly.
The light does not work.Not plugged in.
The circuit breaker tripped or a blown fuse. The light button is “OFF".
Vibrations.Check to assure that the Beverage Cooler is level.
The Beverage Cooler seems to make too much noise.The rattling noise may come from the flow of the refrigerant, which is normal.
As each cycle ends, you may hear gurgling sounds caused by the flow of refrigerant in your Beverage Cooler.
Contraction and expansion of the inside walls may cause popping and crackling noises.
The Beverage Cooler is not level.
The door will not close properly.The door is misaligned.
The Beverage Cooler is not level. The gasket is dirty.
The shelves are out of position.
Display flashes Error message “EO"Connection failure - there is a wire or component that is not connected correctly.

Display flashes Error message “E1"Temperature sensor failure.

Display flashes Error message “E2"Defrost sensor (Coil Sensor) failure.
Display flashes Error message “HH" Display flashes Error message “LL"Temperature of inner cabinet is over 99°F / 37°C Temperature of inner cabinet is under 32°F / 0°C