The reason for the incomplete operation of the thermostat can be a breakdown of the device itself, as the problems with the voltage in the power supply and not only. Below are the tables containing information about Daikin thermostats. In each table you will find information about different models of this brand: fault codes, its causes and repair methods.
Error | Cause |
---|---|
A1 | Indoor unit PCB abnormality |
PCB | Freeze-up protection or high pressure control |
A5 | Fan motor or related abnormality |
A6 | Indoor heat exchanger thermistor abnormality |
C4 | Room temperature thermistor abnormality |
C9 | Humidity sensor abnormality |
CC | Outdoor unit PCB abnormality |
E1 | OL activation (compressor overload) |
E5 | Compressor lock |
E6 | DC fan lock |
E7 | Input overcurrent detection |
E8 | Discharge pipe temperature control |
F3 | High pressure control in cooling |
F6 | Compressor sensor system abnormality |
H0 | Damper abnormality |
H1 | Position sensor abnormality |
H6 | DC voltage / DC current sensor abnormality |
H8 | Outdoor air thermistor abnormality |
H9 | Discharge pipe thermistor abnormality |
J3 | Outdoor heat exchanger thermistor abnormality |
J6 | Liquid pipe thermistor abnormality |
J8 | Gas pipe thermistor abnormality |
J9 | Abnormal temperature in electrical box |
L3 | Temperature rise in radiation fin |
L4 | Output overcurrent |
L5 | Radiation fin thermistor abnormality |
P4 | Fan motor system abnormality / fan lock |
P9 | Heater wire abnormality |
PA | Humidification fan outlet thermistor abnormality / abnormal heater temperature |
PH | Insufficient gas |
U0 | Over voltage protection (OVP) / low voltage protection (LVP) |
U2 | Signal transmission error (indoor unit – outdoor unit) |
Outdoor unit PCB abnormality or communication circuit abnormality | |
U4 | Signal transmission error on outdoor unit PCB |
U7 | Incompatible power supply between indoor unit and outdoor unit |
UA | Incomplete setting for hose length |
Fault code | Description | Cause for the fault |
---|---|---|
AU | Auto Damper | Control setup indicator damper is in “automatic” mode. |
Au | Auto HP/E | Control setup indicator heat pump electric is in automatic changeover mode (HP/E). |
bo | Brown Out or Low Voltage | Brown Out – Control monitors input voltage to prevent relay chattering. When voltage drops below 17 VAC, outputs are disabled until voltage input increases to 20 VAC or greater. |
bY | HP/E Bypass | Control setup indicator, electric heat is bypassed when OCS > 40°. |
CE | LUI Communication | Communication Error, connection between LUI and control board. |
CL | Damper Closed | Control setup indicator damper is in “closed” mode. |
CF | Coil Freeze Protection | Indoor coil is < 32° for at least 5 minutes. Compressor and outdoor fan stop and indoor fan continues to run for active defrost. Protection feature and the displayed code are dismissed when indoor coil temperature rised above 49°F. |
Hi | Temperature Limiting | Hi Room Room Temperature Display Indication ONLY – Indoor air temperature is 5° above Maximum set point. Displayed code is dismissed when IAS temperature is < 5° from Max set point as adjusted in the Set Up Mode. |
LA | Low Ambient Lockout | Unit is in cooling mode and outdoor air < 25°. Compressor will cut out. |
m | Slave Unit Set to be Controlled by a Master Unit | When slave unit jumper for Control Select is positioned over SEC, slave unit is set to be controlled by a Master control unit. |
LC | Control Lockout – Lockout Mode | Displays for 5 seconds when any button is pushed when in the “lockout mode”. To initiate, hold MODE button for 10 seconds. |
Lo | Temperature Limiting | Low Room Room Temperature Display Indication ONLY – Indoor air temperature is < 5° below minimum set point. Displayed code is dismissed when IAS temperature is > 5° from Minimum set point as adjusted In the Set Up Mode. |
nL | Control Lockout – Normal Control | Displays for 5 seconds to confirm normal mode of operation when control lock out turned ofT. Initiate by holding MODE button for 10 sec. |
rF | Room Freeze Protection | Room temperature <41°. Damper closes (Premium board) and unit goes into heat mode. |
Sh | Jumper Status | Missing Shunt or not properly installed. |
El | Indoor Air Sensor | Indoor Air Thermister Failure. Sensor missing or Short. |
E2 | Indoor Coil Sensor | Indoor Coil Thermister Failure. Sensor missing or Short. |
E3 | Outdoor Coil Sensor | Outdoor Coil Thermister Failure. Sensor missing or Short. |
E4 | Outdoor Air Sensor | Outdoor Air Thermister Failure. Sensor missing or Short. |
E5 | Heat Fan Lock Out Sensor | Heat Fan Lock Out Sensor Failure, missing, short on control board or heating medium >250°F. Check for installation/connection of HFLO sensor. Should be on coil return line. |
Error Codes | Description | |
---|---|---|
System | 0 | Normal |
uo | Refrigerant shortage | |
U2 | Low-voltage detection or over-voltage detection | |
U4 | Signal transmission error (between indoor unit and outdoor unit) | |
UA | Unspecified voltage (between indoor unit and outdoor unit) | |
Indoor | A1 | Indoor unit PCB abnormality |
Unit | A5 | Freeze-up protection control or heating peak-cut control |
A6 | Fan motor (DC motor) or related abnormality | |
C4 | Indoor heat exchanger thermistor or related abnormality | |
C9 | Room temperature thermistor or related abnormality | |
Outdoor | E1 | Outdoor unit PCB abnormality |
Unit | E5 | OL activation (compressor overload) |
E6 | Compressor lock | |
E7 | DC fan lock | |
ES | Input overcurrent detection | |
EA | Four-way valve abnormality | |
F3 | Discharge pipe temperature control | |
F6 | High pressure control in cooling | |
HO | Compressor system sensor abnormality | |
H6 | Position sensor abnormality | |
HS | DC voltage / current sensor abnormality (09/12 class only) | |
H9 | Outdoor temperature thermistor or related abnormality | |
J3 | Discharge pipe thermistor or related abnormality | |
J6 | Outdoor heat exchanger thermistor or related abnormality | |
L3 | Electrical box temperature rise | |
L4 | Radiation fin temperature rise | |
L5 | Output overcurrent detection | |
P4 | Radiation fin thermistor or related abnormality |
Symptom | Possible Cause | Action |
---|---|---|
Cool ON or Heat ON is displayed, but no warm or cool air is coming from the registers. | 1. The heating equipment turns on the fan when the furnace has warmed up to a setpoint. | 1. Wait one minute after seeing the ON icon and then check the registers. |
2. Heating or cooling equipment is not operating. | 2. Check Heating and Cooling system. | |
“Service“ Flashing on and off. | Control EEPROM write error. | Press any key and Check / Re-enter Setup Choices. |
“Service” solid on and in temperature display. | Indoor temperature sensor open or shorted | Replace Control |
Display will not come on. | 1. Blown fuse or tripped circuit breaker. | 1. Replace fuse or reset breaker. |
2. Furnace power switch OFF. | 2. Turn switch to ON. | |
3. Furnace blower compartment door or panel loose or not properly installed. | 3. Replace door panel in proper position to engage safety interlock or door switch. | |
Temperature display is incorrect. | Temperature display needs calibration. | Calibrate Sensor. |
Cannot set Heating setpoint above 80 degrees | Deadband between Heating and Cooling set to high | Decrease Deadband setting . |
Temperature setting will not change. (Example: Cannot set heating higher or cooling lower). | 1. Upper and/or lower temperature limits were reached. | 1. Check the temperature setpoints: |
Heating limits are 40 – 85F. | ||
Cooling limits are 65 – 90F. | ||
2. “Keypad locked” is displayed on LCD. | 2. Unlock keypad – press Up+Down arrow together until icon disappears. |