Sharp air conditioner error codes allow to remove many hitches of equipment on one`s own. You can identify Sharp air conditioner error codes with the help of the table presented below. Everything is coherent here, even for a simple user.
LAMP INDICATION | REMEDY |
---|---|
The “LOW” Operation Indicator Light (Clean Air) blinks. | Fan motor disconnected or abnormal. Operation stops. • Pressing the POWER ON/OFF button will reset the error display. |
The “Auto” Operation Indicator Light (Clean Air) blinks. | Microcomputer Errors. • Remove the power plug, wait for a while, then reinsert the plug and try operating the device again. |
The “Humidity Indicator Light (30)” blinks. | Temperature/Humidity Sensor Errors. • Remove the power plug, wait for a while, then reinsert the plug and try operating the device again. |
Error code | Fault |
---|---|
EO | Pump Failure |
E1 | Compressor High Pressure Protection |
E2 | Indoor Frost-Proof Protection |
E3 | Compressor Low Pressure Protection |
E4 | Compressor Exhaust High Temperature Protection |
E5 | Compressor Overheat And Inverter Driving Protection |
E6 | Communications Failure |
E8 | Indoor Fan Protection |
E9 | Full Water Protection |
FF | Connected control communications Failure |
FO | Failure of Indoor Room Sensor at Air Intake |
F1 | Failure of Evaporator Temp. Sensor |
F2 | Failure of Condenser Temp. Sensor |
F3 | Failure of Outdoor Ambient Sensor |
F4 | Failure of Exhaust Temp. Sensor |
F5 | Failure of Indoor Room Sensor at Wire Controller |
EE | Buttons are locked (not failure) |