Samsung conditioner error codes



Samsung air conditioners are fitted with a forward system of self-diagnostics, based on the results of which the system in case of a certain malfunction revelation blocks operation of the unit, simultaneously informing the user of the cause of a breakdown. If Samsung air conditioner not working one can remove errors of air conditioners with the help of a corresponding instruction on malfunction decoding. The instruction of the type can be found below.

Samsung AC030JXADCH air error codes

Air conditioners of the series Samsung AC0…JXADCH belong to the classical models of Samsung air conditioning equipment. They use R-410A refrigerant. This equipment consists of indoor and outdoor units, fuse and control. The air guide duct for this series is not provided by Samsung.

Error number Explanation
E471 Outdoor unit EEPROM Read/Write error (H/W)
E470 Outdoor unit EEPROM Read/Write error (Option)
E202 Communication error between indoor unit and outdoor unit (When there is no response from indoor units after tracking is completed)
E201 Communication error between indoor unit and outdoor unit (Pre tracking failure or when actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power supply (The error occurs with the failure regardless of the number of devices)
E203 Communication error between outdoor unit inv – main micom (For PF #4~#6 controller, error will be determined from the time when compressor turns on)
E221 Error on outdoor temperature sensor (Short or Open)
E108 Error due to repeated communication address
E251 Error on discharge temperature sensor of compressor 1 (Short or Open)
E231 Error on outdoor COND OUT sensor (Short or Open)
E320 Error on OLP sensor (Short or Open)
E485 Error on input current sensor of inverter 1 (Short or Open)
E474 Error on IPM Heat Sink sensor of inverter 1 (Short or Open)
E425 Reverse phase or open phase
E422 Blockage detected on high pressure pipe
E554 Gas leak detected
E416 System stop due to discharge temperature
E463 System stop due to OLP temperature control
E458 Fan speed error
E462 System stop due to full current control
E404 System stop due to overload protection control
E590 Inverter EEPROM Checksum error
E464 System stop due to DC Peak
E473 Comp Lock error
E465 Compressor overload prevention
E468 Error on current sensor (Short or Open)
E461 Error due to operation failure of inverter compressor
E467 Error due to abnormal rotation of the compressor or unconnected wire of compressor
E469 Error on DC-Link voltage sensor (Short or Open)
E472 AC Line Zero Cross Signal out
E475 Error of inverter fan 2
E660 Error of inverter Boot Code
E500 IPM over heat error on inverter 1
E484 PFC Overload (Over current) Error
E466 DC-Link voltage under/over error
E403 Compressor down due to freeze protection control
E440 Heating operation restricted at outdoor temperature over TheatJiigh value (default: 30 °C)
E441 Cooling operation restricted at outdoor temperature below Tcooljow value (default 0°Q
E556 Error due to mismatching capacity of indoor and outdoor unit
E557 DPM remote controller option error
E198 Error on thermal fuse of indoor unit (Open)
E121 Error on room temperature sensor of indoor unit (Short or Open)
E122 Error on EVA IN sensor of indoor unit (Short or Open)
E123 Error on EVA OUT sensor of indoor unit (Short or Open)
E154 Indoor fan error
El 53 Error on float switch (2nd detection)
E508 Smart install is not installed

Samsung ACC2400C air error codes

Air conditioners Samsung ACC2400C belong to the cassette-type air conditioners. This is the most successful option for rooms with suspended ceiling and a large area, they can be installed between the suspended ceiling and the usual one. Installation of this type of air conditioners is much easier than ща other split systems. The system of work of this air conditioning includes cooling and filtration of air and its feeding back through the distribution grids.

Error Code Meaninq Checkina area
1 Indoor unit thermistor sensor error – Indoor unit thermistor sensor
– PCB of the indoor unit
5 Indoor unit pipe thermistor sensor error – Indoor unit pipe thermistor sensor
– PCB of the indoor unit
6 Outdoor unit thermistor sensor error – Outdoor unit thermistor sensor
– PCB of the outdoor unit
9 Float switch error – Drain pump, Float switch
– Drain system
– DIP switch(SW2) of the indoor unit (The No.2 and No.4 switches must be at “ON” position.)
A A Indoor and Outdoor communication error – Communication cables of indoor and outdoor units
– PCB of indoor and outdoor units
C Wired remote controller communication error – Wired remote controller cables, Wired remote controller
– Main/Sub PCB of the indoor unit
D Outdoor pipe thermistor sensor error – Outdoor pipe thermistor sensor
– PCB of the outdoor unit

Samsung APH450PG air error codes

Air conditioners Samsung APH450PG are floor-mounted air-conditioning units. The refrigerant R-22 is used in the system of these air conditioners. Air conditioners have remote control, timer and air filter. There is a possibility of regulation of the air flow from such air conditioners. They are produced in a classical white color of the body frame.

Temperature display Cause Corrective actions
E1 Short of indoor temperature sensor
Open of Indoor temperature sensor
Check of departure of indoor temperature sensor
Check of PCB open/short
E5 Short of indoor heat exchanger sensor
Open of indoor heat exchanger sensor
Check of indoor exchanger sensor departure
Check of PCB open/short
Replacement of sensor
E6 Short of outdoor heat exchanger sensor
Open of outdoor heat exchanger sensor
E7 Short of heater temperature sensor
Open of heater temperature sensor
Check of heater wiring diagram
Check of sensor attachment location
EL When the electrical heater is over heated Check of heater temperature sensor departure
Check of PCB open/shore
Replacement of sensor

Samsung AVXC1H022 series air error codes

Air conditioners of the series AVXC1H022 are cassette-type units. Samsung air conditioners of the cassette type are installed in spacious rooms with suspended ceilings. Due to the latest technology, the proportions of Samsung air conditioners are minimal ones. The presence of air conditioning in the room can be found not by the noise of operating equipment, but by the cool air. The air is evenly distributed in four directions.

Error No.(Ordered by priority) Error Meaning
E221 Outdoor temperature sensor(Short or Open)
E251 Digital comp.1 discharge temperature sensor(Short or Open)
E256 Fixed comp.1 discharge temperature sensor(Short or Open)
E257 Fixed comp.2 discharge temperature sensor(Short or Open)
E258 Fixed comp.3 discharge temperature sensor(Short or Open)
E291 High pressure sensor(Short or Open)
E296 Low pressure sensor(Short or Open)
E271 Comp.1 Sump temperature sensor(Short or Open)
E231 COND OUT sensor(Short or Open)
E307 Oil balance sensorl (Short or Open)
E308 Suction sensor(Short or Open)
E311 Double pipe sensor(Short or Open)
E425 Reverse phase or missing phase
E452 Instant power off error
E440 Forbid heat mode operation when outdoor temperature is over 30°C
E442 Forbid an operation during heat mode with refrigerant charging operation when outdoor
temperature is over 15°C
E443 Start prohibition by refrigerant pressure error
E431 Equal oil valve 1 self diagnosis
E202 Communication error between indoor and outdoor unit (When not received in every room after completing the tracking)
E201 Communication error between the indoor unit and outdoor uniL (Pre tracking failure or different unit number between set units and indoor units.)
E203 Communication error between main of outdoor unit and sub MICOM or between units
E407 Comp, down by high pressure
E410 Comp, down by low pressure
E403 Comp, down by the freezing protection control
E413 Comp, down by the sump protection control
E554 Loading failure
E416 Comp, down by the discharge temperature sensor
E241 COND OUT sensor breakaway
E269 Suction temperature sensor breakaway
E453 Fan motor hicfi temperature error
E454 Fan motor RPM error
E455 Fan motor IPM high temperature error
E458 CT_over current
E457 Fan motor reverse rotation error
E162 Outdoor unit EEPROM error
E560 Switch option setting error(rvot applied)
E428 Comp down by compression ratio control
E121 Room temperature sensor open or short error
E122 Indoor unit EVAP IN Sensor open or short error
E123 Indoor unit EVAP OUT Sensor open or short error
E154 Indoor unit fan error
E124 Communication error sends from indoor unit
E153 Indoor unit floating S/V error(When 2“ detection)
P701 Indoor unit floating S/V error(When 1“ detection)
E152 Indoor unit EEV close failure(When 2“ detection)
P702 Indoor unit EEV close failure(When 1“ detection)
E151 Indoor unit EEV open failure(When 2 detection)
P703 Indoor unit EEV open failure(When 1“ detection)
E128 Indoor unit EVA IN sensor breakaway
E129 Indoor unit EVA OUT sensor breakaway
E131 Indoor unit heater sensor error
E265 Digital compl Sump temperature sensor breakaway. Fixed compl Sump temperature sensor breakaway
E267 Fixed comp2 Sump temperature sensor breakaway
E268 Fixed comp3 Sump temperature sensor breakaway
E262 Fixed compl Discharge temperature sensor breakaway
E263 Fixed comp2 Discharge temperature sensor breakaway
E264 Fixed comp3 Discharge temperature sensor breakaway
E456 Fan motor over current error
E461 CTJow current
Ch Prohibit starting during operation of the Crack case heater

Samsung IDH1800E air error codes

Air conditioners of the type Samsung IDH1800E have only one internal block. They have a centralized controller, which is installed on the wall. These units can also have a wireless remote controller with a display. However, it can be an optional accessory.

ERROR CODE ERROR DESCRIPTION
El Indoor unit room thermistor error
E5 Indoor unit pipe thermistor error
E6 Outdoor unit thermistor error
E9 Float switch open error
EA Communication error between indoor unit and outdoor unit
EC Communication error between wired remote controller and indoor unit
ED Outdoor unit pipe thermistor error
Reservation LED flickering(1Hz period) Indoor temperature sensor abnormal
Operation LED and reservation LED flickering (1Hz period) Indoor pipe temperature sensor abnormal
Operation LED and filter LED flickering (1 Hz period) Outdoor temperature sensor abnormal
Reservation LED filter LED alternating flickering (1Hz period) Float switch open abnormal
Reservation LED and filter LED flickering (1Hz period) Indoor and outdoor communication abnormal
Operation LED and reservation LED alternating flickering (1Hz period) Wired remote controller communication abnormal
Filter LED flickering (1Hz period) Outdoor pipe temperature sensor abnormal
1 Indoor unit room thermistor error
5 Indoor unit pipe thermistor error
6 Outdoor unit thermistor error
9 Float switch open error
A Communication error between indoor unit and outdoor unit
C Communication error between wired remote controller and indoor unit
D Outdoor unit pipe thermistor error

Samsung NX 1 air error codes

Samsung NX 1 is a mirrorless camera with interchangeable lenses. The front view of the camera is pretty standard. There are just l fixing mechanism of the lens and button of the repeater from the visible controls. There is a dust and moisture proof coating of the frame. The menu has a very wide selection of settings. The camera has a wide range of control interfaces for capturing and transfer of data. The camera is quickly and easily configurable.

Error messages Suggested remedies
Lens is locked The lens is locked. Rotate the lens counter- clockwise until you hear a click, (p. 58)
Card Error • Turn off the camera, and then turn it on again.
• Remove the memory card and insert it again.
• Format the memory card.
Low Battery Insert a charged battery or recharge the battery.
No Image File Capture photos or insert a memory card that contains photos.
File Error Delete the damaged file or contact a service center.
Memory Full Delete unnecessary files or insert a new memory card.
Card Locked You can lock SD, SDHC, or SDXC cards to prevent files from being deleted. Unlock the card when shooting, (p. 190)
Unable to capture a photo because folder and file number on the memory card reached the maximum values. Reset the folder number? File names do not match the DCF standard. Follow the on-screen instructions to reset the folder number.
Error 00 Turn off your camera and remount the lens. If the message still appears, contact a service center.
Error 01/02 Turn off your camera, remove the battery, and insert again. If the message still appears, contact a service center.