American Standard Furnace Error Codes

If you need to know what the signals of your American Standard furnace mean, you can find the necessary information about it here. The tables presented on this page are the lists of American Standard furnace error codes with their explanations and possible problem solutions.

The signals are sorted by LED color and number of flashes which you observe. The meanings are given for all kinds of faults, for example, 2 flashes are described as system lockout, and 3 flashes have several meanings possible. For some modifications there are also alert codes given to provide better understanding of nature of the issue.

American CDB1 Standard Furnace Error Codes

LED Color Fault LED Alert Code Description Control Display
Red 90 Excessive Communication Errors N/A
1 Flash 91 Loss of Heat/Cool Demand Message (COMM) ERR 91
Loss of Bit Master (Clock Signal)
2 Flash Defrost Fault A
3 Flash 68 Defrost Fault B and/or C N/A
4 Flash Defrost Fault A and [B and/or C]
5 Flash 67 Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67
6 Flash Coil Temperature Sensor Fault (Out of Range – Open or Shorted)
Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79
7 Flash 79 Low Pressure Cut Out Fault Heat/Cool Lock out
Low Pressure Cut Out Fault (Open outside of defrost Cycle-Short lock out) Wait n
10 Flash 102 Y2 without Y1 – Miswire (24 volt mode only) N/A
11 Flash 67 Liquid Temperature Sensor Fault (Out of Range – Open or Shorted) N/A
12 Flash 113 Liquid Pressure Sensor Fault (Out of Range – Open or Shorted) ERR 113
13 Flash 67 External Outdoor Temperature N/A
Sensor Fault (Out of Range – Shorted)
PM Missing with local copy (Operational) ERR 114
Bad Data in PM with local copy (Operational) N/A
14 Flash 114 Bad Data in PM no local copy (Not Operational) ERR 114
PM Missing with no local copy (Not Operational)
15 Flash * 50 Duplicate OD Temperature Sensor * N/A
16 Flash * 123 Demand Configuration Fault * N/A

American TUY060R9V3W Standard Furnace Error Codes

LED Color Charge Assist™ (CA) LEDs Flashing Description
Green CHARGED Off Charged or not in CA Mode
On Charge is Correct
Y1 On 1 st stage compressor requests
Y2 On 2nd stage compressor request
Fast Flash Initialization at Power Up ~ 60 seconds
Med Flash Oil Return Mode ** (Forced Defrost)
STATUS Slow Flash Standard operation
Off Charge Assist™ mode or no power to control
LitePort Occasional Flash For transmitting LitePort™ data
Amber COM Flashing Flash device count when in communication (number of COMM products connected in system); Rapid flashes followed by a pause indicates disrupted communications
Off No power
On Solid at power-up
Flashing See Stabilization Flash Rate
CHARGING Off Not in CA Mode
ADD On System requires refrigerant charge (Control has 24 volt AC output to Charqe Solenoid)
Red ODT Flashing Ambient Temperature is out of range – Ambient Temperature must be above 55°F and below 120°F to enter CA Mode A/ore: ODT LED will flash 1 sec ON/OFF for 30 seconds and the CHARGING LED will flash 5 times per second for 2 seconds, then exit CA.
RECOVER On Need to recover refrigerant – Unit locked out for 1 hour or press mode button to exit Charge Assist™
LOW On Liquid pressure below 90 psig – Liquid pressure must be above 90 psig to enter CA Mode
Note: LOW oressure LED will be on for 30 seconds and the CHARGING LED will flash 5 times per second for 2 seconds, then exit CA.

American AUY060R9V3W Standard Furnace Error Codes

LED Description
2 Flashes System Lockout (Retries or Recycles exceeded)
3 Flashes Draft Pressure Error – Possible problems:
a) Venting problem
b) Pressure switch problem
c) Inducer problem
4 Flashes Open Temperature Limit Switch
5 Flashes Flame sensed when no flame should be present
6 Flashes 115 volt AC power reversed, ignitor (Triac) fault, poor grounding or system voltage too low
7 Flashes Gas valve circuit error
8 Flashes Low flame sense
9 Flashes Open Inducer Limit switch
10 Flashes Inducer communication error
Solid Internal GV error or Low TH voltage
Solid Red w/Solid Green “STATUS” LED Continuous Reset caused by a blown fuse or internal error.