Sharp AX-1100R Microwave Error Codes
Fault code | Definition |
---|---|
F1 | Open Thermal Sensor, due to excessive heat in microwave cavity |
F2 | Shorted thermal sensor |
F3 | Shorted touch pad panel |
F4 | Open humidity sensor |
F5 | Shorted humidity sensor |
F6 | Shorted temperature probe |
F10 | Shorted touch screen |
Probe | Open temperature probe or the probe is not plugged in during a temp cook function. Make sure probe is firmly inserted into the wall of microwave and the food item. |
888, 8888 or PF | It is possible to see this display upon initial installation or after power was restored due to a power failure. This display can be cancelled and normal operation resumed by touching the CLEAR pad. The clock can be reset on models so equipped. |
18 power watch code | Indication of an issue with the electronic control in the microwave. |
Sharp Carousel R-316F Microwave Error Codes
DISPLAY | CONDITION | POSSIBLE CAUSE (In order of probability) |
---|---|---|
F33 | Open temperature sensor (exhaust) | 1. Loose ground screw on the digital programmer circuit |
2. Loose connector CN4 | ||
3. Open temperature sensor (Should read 25k to 85k) | ||
4. Digital programmer circuit failure | ||
F34 | Short temperature sensor (exhaust) (Rare) | 1. Digital programmer circuit failure |
2. Temperature sensor failure | ||
F44 | 1. Shorted membrane switch | |
F01 | Exhaust temperature exceeds 120° C | 1. Burning food in the oven due to overcooking |
F05 | Memory failure | 1. Digital programmer circuit failure |
No Display (Dead) | No voltage supply to the LV transfomer | 1. Right fuse open |
2. Damaged short switch | ||
3. Shorted H.V capacitor, transformer, diode or magnetron (upper) | ||
4. Shorted L.V transformer (Relay board) | ||
5. Digital programmer circuit failure | ||
F81 | Excessive current comsumption (upper H.V circuit) | 1. Open primary latch sw itch |
2. Relay failure RY-3 (Relay Board) | ||
3. Digital programmer circuit failure | ||
F82 | Excessive current comsumption (lower H.V. circuit) | 1. Left fuse open |
2. Open primary latch switch | ||
3. Damaged short switch | ||
4. Shorted H.V capacitor, transformer, diode or magnetron (lower) | ||
5. Relay failure RY-4 (Relay Board) | ||
6. Digital programmer circuit failure | ||
F86 | Shorted contacts of RY-3 | 1. Relay failure RY-3 (Relay Board) |
2. Digital programmer circuit failure | ||
F87 | Shorted contacts of RY-4 | 1. Relay failure RY-4 (Relay Board) |
2. Digital programmer circuit failure |
Sharp KB-6015KW Microwave Error Codes
EE Mode | Reason | Action Required |
---|---|---|
EE 1, EE 2 | Failure of single magnetron | Call for service. |
EE 3 | Both magnetrons failed | |
EE 4 | Voltage too high | |
EE 5 | Voltage too low | |
EE 7 | Oven cavity or component temperature too high | Check that nothing is blocking air intake openings on oven back or that oven exterior is very hot. Correct. Wait a few minutes and try again. If problem persists, call for service. |
EE 8 | Circuit failure | Call for service. |
EE 9 | Maximum cooking time is exceeded. | Press the STOP/CLEAR pad, and re-input by reducing Total Cooking Time or power levels. |
EE 0 | Cooling fan motor and other motor failure. Oven ceiling cover is not installed properly. | Cooling fan motor and other motors: Call for service. |
Oven ceiling cover: Check that oven ceiling cover is properly installed. If problem persists, call for service. |
Other error codes
EE Mode | Reason | Action Required |
---|---|---|
EE 1, EE 2 | Magnetron failure | Call for service |
EE 3 | Both magnetrons failed | |
EE 4 R-23GT, R-24GT and R-25JT only | Voltage too high | If problem is not corrected, call an electrician. |
EE 5 R-23GT, R-24GT and R-25JT only | Voltage too low | If problem is not corrected, call an electrician. |
EE 6, EE10, EE16 | Thermistors failure | Call for service. |
EE 7 | Exhaust air temperature too high | Check that nothing is blocking air intake openings on oven back or that oven exterior is very hot. Correct. Wait a few minutes and try again. If problem persists, call for service. |
EE 8 | Circuit failure | Call for service. |
EE 9 | Maximum time is exceeded | Touch STOP/CLEAR pad, and reprogram correctly. |
EE 0 | Fan lock error | Call for service. |
EE17 | Magnetron temperature too high | Touch STOP/CLEAR pad. Wait a few minutes and try again. If problem persists, call for service. |