11 |
NO FAULT IN RECENT HISTORY DISPLAY- Indicates no faults have occurred within the last five cycles. To read recent fault history, put setup switch “SW-1” in the “ON” position. To clear recent fault history, put setup switch “SW-1” in the “ON” position and jumper thermostat terminals “R”, “W/Wl” and “Y/Y2” simultaneously until an “11” is flashed. |
12 |
BLOWER CALIBRATION LOCKOUT- Indicates RPM calculated for low heat was less than 250 RPM or greater than 1300 RPM on two successive attempts. Auto reset after three hours. Reset power |
13 |
LIMIT SWITCH LOCKOUT- Indicates the occurrence of 10 successive limit trips during high heat or three successive limit trips during low heat. Auto reset after three hours. Check for ^Improper or misaligned limit and/or limit shield. ^Improper high or low heat qas input adjustment. *Stuck high heat solenoid in gas valve. |
14 |
IGNITION LOCKOUT- Control will auto-reset after three hours. |
21 |
INVALID MODEL SELECTION- Indicates model plug is missing or incorrect. |
22 |
SETUP ERROR- Indicates setup switch “SW-1” or “SW-6” is positioned improperly. The following combinations will cause the fault: |
|
^Thermostat call with “SW-1” “ON”, or Thermostat call with “SW-6” “ON”, or “SW-1” and “SW-6” both “ON” together. |
23 |
INVALID BLOWER AIRFLOW SELECTION- Indicates improper “A/C” or “CF” switch setting. The 042 and 14 units can deliver 1-1/2 to 3-1/2 tons A/C and 600 to 1400 CFM for continuous fan. The 060 and 20 unit can deliver 2 to 5 tons A/C and 800 to 2000 CFM for continuous fan. If code is flashing, unit will default tp closest allowable airflow. |
24 |
SECONDARY VOLTAGE FUSE IS OPEN Check for: – Short circuit in secondary voltage (24VAC) wiring. |
|
PRESSURE SWITCH DID NOT CLOSE OR REOPENED – If open longer than five minutes, inducer shuts off for 15 minutes before retry. Check for: – Excessive wind |
31 |
– Proper vent sizing – Defective inducer motor – Low inducer voltage (115VAC) – Defective pressure switch – Inadequate combustion air supply – Restricted vent |
|
– Disconnected or obstructed pressure tubing – Low inlet gas pressure (if LGPS used) If it opens during blower on- delay period, blower will come on for the selected blower off-delay |
33 |
LIMIT CIRCUIT FAULT – Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. |
|
If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset. Check for: – Restricted vent – Proper vent sizing – Loose blower wheel – Excessive wind – Dirty filter or restricted duct system. |
|
– Defective blower motor or capacitor. – Defective switch or connections. – Inadequate combustion air supply (Flame Roll-out Switch open). |
34 |
IGNITION PROVING FAILURE – Control will try three more times before lockout #14 occurs. If flame signal lost during blower on-delay period, blower will come on for the selected blower off-delay. Check for: – Control ground continuity – Flame sensor must not be grounded – Oxide buildup on flame sensor (clean with fine steel wool) |
|
– Proper flame sense microamps (.5 microamps D.C. min., 4.0 – 6.0 nominal). – Gas valve defective or gas valve turned off – Manual valve shut-off – Defective Hot Surface Ignitor – Low inlet gas pressure |
|
– Inadequate flame carryover or rough ignition – Green/Yellow wire MUST be connected to furnace sheet metal |
41 |
BLOWER OUTSIDE VALID SPEED RANGE- Indicates the blower is not operating at the calculated RPM. If this fault occurs in conjunction with fault #44 check wiring to motor otherwise |